MEPworx
Premium Plus
MEPworx 2025 - Now Released
ARKANCE is pleased to announce the release of MEPworx 2025 with enhancements to improve the user experience.
For full...
Premium Plus
MEPworx Mechanical – Updated Radiator databases
by David Wren
In keeping with ongoing development, some of the Radiator databases are revised and updated for MEPworx...
Premium Plus
MEPworx Building – Aragog gbXML Viewer
by David Wren
A new addition to MEPworx 2025 is the Aragog viewer, which enables allows the User to view, validate an...
Premium Plus
MEPworx Wiring – Set up LED light fittings as dual purpose (emergency fittings)
by David Wren
Previously, there has not been an option to set up LED luminaires as Emergency Fittings.Now there is....
Premium Plus
MEPworx - Backup Job / Email Job wizard
by Gary Mann
The Email Job wizard is an effective method of compiling all the required MEPworx project files from va...
Premium Plus
MEPworx. Where can I download MEP Programs?
By Gary Mann
There are several ways to download MEPworx and MEPlinx. Please choose whichever suits you best from the ...
Premium Plus
MEPworx – ‘Help’ for the New Project Wizard & EPW data
by David Wren
When using the New Project Wizard to create a fresh MEPworx Building CYC project, you can now fire up c...
Premium Plus
MEPworx Wiring – Updated Hager CPD DB
By David Wren
In keeping with on-going development, regarding new and updated CPD DBs (Circuit Protective Device Da...
Premium Plus
MEPworx - Unable to Install “Unconfirmed 3845.crdownload”
By Gary Mann
If you have downloaded the latest release of MEPworx using Edge, Internet Explorer or Firefox, you may s...
Premium Plus
MEPworx Lighting – Find and Replace Luminaire
By David Wren
It can be quite common that you need to change the type of light fitting being used in a design project...
Premium Plus
MEPworx Wiring – Transformer Overload Ratings
By David Wren
It is not uncommon for transformers to be designed to run at substantial overloads. Typically, a range ...
Premium Plus
MEPworx – Create 'Arrays' of Public Health appliances
By David Wren
New for MEPworx 2024, is the added facility to insert an Array of Public Health - Standard Draw Off uni...
Premium Plus
MEPworx – Adding and setting up Heat Interface Units (HIUs)
By David Wren
In line with the CIBSE Code of Practice, CP1-2020, Heat Networks have been incorporated via placement o...
Premium Plus
MEPworx - Weather Chooser Utility Program
by Stuart Morgan & David Wren
In Building’s Edit-General dialog on the Further Details tab, Choose - Opens up the M...
Premium Plus
MEPworx Wiring – Revised and updated Siemens CPD DB
By David Wren
The latest version of the Siemens CPD DB has now been raised to Siemens 2023.This new version of the C...
Premium Plus
MEPworx Wiring – NSXm-E Micrologic 4.1 added to Schneider CPD DB
By David Wren
As requested by some of our MEPworx Users, the ComPacT NSXm-E Micrologic 4.1 ranges have been added to ...
Premium Plus
MEPworx – Part L checks updated
By David Wren
In the Lighting program, when the Part L Lighting Compliance Check is selected, the Engineer can view t...
Premium Plus
MEPworx – New Legacy Database sub-folder structure
By David Wren
Databases are continually being revised, updated or superseded by newer versions. This can sometimes ma...
Premium Plus
MEPworx - New Dorman Smith CPD DB
By David Wren
As requested by some of our MEPworx users, we now have a new Dorman Smith CPD Database.
For reasons of ...
Premium Plus
MEPworx – Modifications to Insert Emitter Other
By David Wren
In the Piping program the Insert commands for; Insert Heating - Other Emitter and Insert Cooling - Cool...
Premium Plus
MEPworx - Unable to Install “Unconfirmed 3845.crdownload”
By Gary Mann
If you have downloaded the latest release of MEPworx using Edge, Internet Explorer or Firefox, you may s...
Premium Plus
MEPworx 2024 - Now Released
Cadline is pleased to announce the release of MEPworx 2024, including new Mechanical enhancements such as the additio...
Premium Plus
How does the MEPlinx installer (previously Cylink) detect the Revit installation?
By Simon Brown
There have been a few recent enquiries to our support service regarding the installation of the MEPlin...
Premium Plus
MEPworx - Duct sizes to BSEN 1506
By Gary Mann
I am often asked “Why is a Duct size not available in the Ducting Program?”. The answer is that it proba...
Premium Plus
MEPworx - Energy Plus Weather (EPW) data in MEPworx 2024
By Stuart Morgan & David Wren
This release of MEPworx includes the ability to make use of hourly weather data in comm...
Premium Plus
MEPworx Wiring – Update Eaton CPD DB for Wiring
By David Wren
As requested by some of our MEPworx users, the latest edition of the Eaton CPD DB has recently been upd...
Premium Plus
MEPworx Wiring – Revised and updated Hager CPD DB
By David Wren
Working with Hager UK, the latest version of the Hager CPD DB has now been raised to Hager 2023.
This ...
Premium Plus
MEPworx Wiring – RCBO or AFDD-RCBO Internal RDC Trip detail
By David Wren
Where the selected CPD Type has an Internal RCD Earth Trip unit, e.g. RCBO or AFDD-RCBO, the Type of RC...
Premium Plus
MEPworx 2023 1.1
Cadline is pleased to announce the release of MEPworx 2023 1.1 to cater for the second tranche of electrical regulati...
Premium Plus
MEPworx - Using Pods in PH (Plumbing)
By Gary Mann
I have seen several methods of modelling an integrated Pod, but some fall short on optimising pipe sizes...